TS50 Medical/General waste incinerator

Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: -
 Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste
 Waste density: 125 to 350Kg/M3
 Waste CV: 4000 KCAL/kg
 Moisture content: 10-25%
 Estimated ash residue: 5-10%
 Nominal capacity: 30Kg/hour batch load
 Secondary chamber: 0.5 second @ 850oC
Equipment 
1No. Surefire TS50/1 Manual Load Incinerator comprising: -
 Manual loading door
 Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long 
 Full sized bulk load/ash removal door
 1 off diesel-fired ignition burner – temperature  controlled
 1 off combustion air supply fan and distribution system, automatic control
 High capacity secondary combustion chamber 0.5 second @>850oC
 1 off diesel-fired afterburner – temperature controlled
 Control panel – automatic operation
 Temperature indication primary and secondary chambers 0-1200oC
 Refractory lined flanged chimney to a height of 6M